ADT-24T

FULL NAME ADT-24T

 

DESCRIPTION

Unit doses fuel to working engine nozzles in all modes, limits gases temperature after turbine on launch and on working modes, controls launch, and in defined modes range provides automatic engine shutdown.

 

CHARACTERISTICS

Working fluid TS-1, T-1, T-2, RT
Working fluid temperature -50…+60 °С
Environment temperature -60…+80 °С
Maximum fuel pressure:
– on input 85 kgf/cm2
– on output 70 kgf/cm2
Dry mass 15,5 kg

 

INTEGRATION

Aircraft An-24